Turbonetics T3 60-1 | Thermal Zero Staging Site https://staging.thermalzero.com Thermal Heat Insulation Blanketing and Materials Thu, 12 Aug 2021 19:21:31 +0000 en-US hourly 1 https://wordpress.org/?v=6.7.2 Universal Externally Wastegated T3 Turbo Heat Insulation Blanket – Lava https://staging.thermalzero.com/product/universal-externally-wastegated-t3-turbo-heat-insulation-blanket-lava/ Mon, 20 Aug 2018 22:19:59 +0000 http://new.thermalzero.com/?post_type=product&p=3351
  • Easy to install with stainless lacing anchors and supplied wire
  • Design fits most externally wastegated T3 turbo housings
  • Internally and externally rated to over 2500°F direct heat
  • Highly durable and heavy duty Lava outer jacketing
  • Made with pride in the USA.
  • The post Universal Externally Wastegated T3 Turbo Heat Insulation Blanket – Lava first appeared on Thermal Zero Staging Site.]]>
    Universal Externally Wastegated T3 Lava Turbo Blanket.  Fits most all T3 turbo exhaust housings and some T4.

    Thermal Zero turbo blankets go above and beyond when it comes to heat tolerance and durability.  The inner layer of the turbo blanket can handle over 2500 degrees Fahrenheit of direct heat.  The blankets are made with high quality 1 inch thick 6 pound density ceramic insulation material.

    Our Lava line of blankets are different from our other turbo blankets in that they feature an outer jacketing that is made from an extremely heavy duty and high quality pulverized lava rock fiber instead of silica impregnated fiber.  This lava material is actually different than what any other turbo blanket manufacturer uses in that it features an aluminum bonded layer on the inside of the blanket to further reflect the small amount of radiant heat which makes it through the ceramic layer.  With this combination of materials we have seen up to 90% efficiency out of a Lava blanket on certain applications.

    Due to the durability and extremely high heat rating  (3000°F) of the Lava material; this blanket is ideal for applications where there is top mount turbo manifold or or heat sources which could come in contact with the outside of the blanket.

    Since vibration on a turbocharger is inevitable we have created a more durable design.  Our turbo blankets feature a knitted wire mesh inner layer that separates the insulation material from the turbocharger housing, greatly increasing durability and reducing breakdown.

    Installing a Thermal Zero Lava Turbo blanket will cut down up to 90% of direct heat emitted from your turbocharger.  In turn this will allow the turbo to spool faster and be more efficient.

    Not sure if this blanket will fit your turbo.  Check the known good fit turbo models below or measure your turbo and check the measurement picture above to verify it will be a good fit.

    Suggested Turbocharger Models:
    Turbonetics T3 T04E Garrett
    GT3582R / GTX3582R
    Garrett
    GT32
    Garrett
    GT3076R / GTX3076R
    Garrett
    GT30R /GT35R
    Turbonetics T3 60-1 Turbonetics T3 62-1 Precision 5831 Precision 5431 Garrett
    GTX2860R
    Borg
    Warner S200 series
    Borg
    Warner S300 series
    Precision T3 6262 Precision 4831 Garrett
    GTX3067R
    Tial GT28 Tial GT30 Tial GT35 Garrett
    GTX3071R

    All Thermal Zero blankets are hand made here in Cincinnati, Ohio USA. If you can’t find exactly what you need or have questions about fitment? Call us at 513.696.9727, we probably make it or can help you.

    The post Universal Externally Wastegated T3 Turbo Heat Insulation Blanket – Lava first appeared on Thermal Zero Staging Site.]]>
    Universal T3 Turbo Blanket for Externally Wastegated Turbo https://staging.thermalzero.com/product/universal-t3-turbo-blanket-for-externally-wastegated-turbo/ Mon, 20 Aug 2018 21:04:29 +0000 http://new.thermalzero.com/?post_type=product&p=3338
  • Easy to install blanket
  • Design fits most externally wastegated T3 turbo housings
  • Internally rated to over 2500°F direct heat
  • Durable high temperature exterior shell material
  • Made with pride in the USA
  • The post Universal T3 Turbo Blanket for Externally Wastegated Turbo first appeared on Thermal Zero Staging Site.]]>
    Universal External Wastegated T3 Turbo Blanket.  Fits most all T3 turbo exhaust housings and some T4.

    Thermal Zero turbo blankets go above and beyond when it comes to heat tolerance and durability.  The inner layer of the turbo blanket can handle over 2500 degrees Fahrenheit of direct heat.  The blankets are made with high quality 1 inch thick 6 pound density ceramic insulation material and covered with a silicone based outer shell that is colored either Black, Red, Blue, Chrome, or Gray. Since vibration on a turbocharger is inevitable we have created a more durable design.  Our turbo blankets feature a knitted wire mesh inner layer that separates the insulation material from the turbocharger housing, greatly increasing durability and reducing breakdown.

    Installing a Thermal Zero Turbo blanket will cut down up to 80% of direct heat emitted from your turbocharger.  In turn this will allow the turbo to spool faster and be more efficient.

    Not sure if this blanket will fit your turbo.  Check the known good fit turbo models below or measure your turbo and check the measurement picture above to verify it will be a good fit.

    Suggested Turbocharger Models:
    Turbonetics T3 T04E Garrett
    GT3582R / GTX3582R
    Garrett
    GT32
    Garrett
    GT3076R / GTX3076R
    Garrett
    GT30R /GT35R
    Turbonetics T3 60-1 Turbonetics T3 62-1 Precision 5831 Precision 5431 Garrett
    GTX2860R
    Borg
    Warner S200 series
    Borg
    Warner S300 series
    Precision T3 6262 Precision 4831 Garrett
    GTX3067R
    Tial GT28 Tial GT30 Tial GT35 Garrett
    GTX3071R

    All Thermal Zero blankets are hand made here in Cincinnati, Ohio USA. If you can’t find exactly what you need or have questions about fitment? Call us at 513.696.9727, we probably make it or can help you.

    The post Universal T3 Turbo Blanket for Externally Wastegated Turbo first appeared on Thermal Zero Staging Site.]]>